- Description: power base - TeSys U - 12 A - screw clamps control
- Product weight: 1.98 lb(US) (0.9 kg)
- IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1
- Standards: CSA C22.2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrier
- Device short name: LUB
- Width: 1.77 in (45 mm)
- Height: 5.71 in (145 mm)
- Depth: 4.96 in (126 mm)
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1 3
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 15000000 cycles
- Tightening torque: Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) flatControl circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) Philips no 1Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) flatPower circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) Philips No 2
- Connections - terminals: Power circuit: screw clamp terminals 2 cable 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: rigid - without cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: rigid - without cable endPower circuit: screw clamp terminals 1 cable 0...0.02 in² (1...10 mm²) - cable stiffness: rigid - without cable endPower circuit: screw clamp terminals 1 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 1 cable 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - without cable endPower circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: rigid - without cable end
- Range: TeSys
- [Ith] conventional free air thermal current: 12:00 AM
- System Voltage: 230 V440 V500 V690 V
- Operating rate: 60 cyc/mn
- Product name: TeSys U
- [Uc] control circuit voltage: 110...220 V DC110...240 V AC 50/60 Hz24 V AC 50/60 Hz24 V DC48 V AC 50/60 Hz48...72 V DC
- Shock resistance: 10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27
- Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-274 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
- [Ie] rated operational current: 12 A at <= 440 V12 A at 500 V9 A at 690 V
- Utilization category: AC-41AC-43AC-44
- Poles description: 3P
- Operating time: 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit75 ms closing with LUCM control circuit
- Auxiliary contact composition: 1 NO + 1 NC
- Heat dissipation: 2 W for control circuit with LUCA, LUCB, LUCC, LUCD1.7 W for control circuit with LUCM
- Auxiliary contacts type: Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
- Immunity to micro breaks: 3 ms
- Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
- Product or component type: Non reversing power base
- Network frequency: 40...60 Hz
- Product certifications: BVATEXLROS (Lloyds register of shipping)ULGOSTGLABSASEFADNVCSACCC
- Device application: Motor
- [Ics] rated service breaking capacity: 10 kA 500 V4 kA 690 V50 kA 230 V50 kA 440 V
- Suitability for isolation: Yes
- Typical current consumption: 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD150 mA at 24 V DC I maximum while closing with LUCM280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V DC I rms sealed with LUCM
- Safety reliability level: B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Ambient air temperature for operation: -13...140 °F (-25...60 °C) with LUCM-13...158 °F (-25...70 °C) with LUCA, LUCB, LUCC, LUCD
- Ambient air temperature for storage: -40...185 °F (-40...85 °C)
- Fire resistance: 1202 °F (650 °C) conforming to IEC 60695-2-121760 °F (960 °C) parts supporting live components conforming to IEC 60695-2-12
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
- Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2
- Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
- Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
- Non-dissipating shock wave: 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-21 kV serial mode 48...220 V DC conforming to IEC 60947-6-22 kV common mode 24...240 V AC conforming to IEC 60947-6-22 kV common mode 48...220 V DC conforming to IEC 60947-6-2
- Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUB12 . Santa Clara Systems carries 10,459 items from Telemecanique.
- Power Base - Tesys U - 12 A - Screw Clamps Control
Alternates
Common Typos
- 1U812
- 1U81Z
- 1U8I2
- 1U8IZ
- 1U8L2
- 1U8LZ
- 1UB12
- 1UB1Z
- 1UBI2
- 1UBIZ
- 1UBL2
- 1UBLZ
- IUB12
- IUB1Z
- IUBI2
- LU812
- LU81Z
- LU8I2
- LU8IZ
- LU8L2
- LU8LZ
- LUB1Z
- LUBI2
- LUBIZ
- LUBL2
- LUBLZ
Appended Numbers
- LUB12-A
- LUB12-B
- LUB12-C
- LUB12-D
- LUB12-E
- LUB12-F
- LUB12-G
- LUB12-H
- LUB12-I
- LUB12-J
- LUB12-K
- LUB12-L
- LUB12-M
- LUB12-N
- LUB12-O
- LUB12-P
- LUB12-Q
- LUB12-R
- LUB12-S
- LUB12-T
- LUB12-U
- LUB12-V
- LUB12-W
- LUB12-X
- LUB12-Y
- LUB12-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier