• Festo CPX-E-PN Barcode

CPX-E-PN

Product Summary:

  • Ambient temperature: -5 °C ... 50 °C
  • Dimensions W x L x H: 42.2 mm x 76.5 mm x 125.8 mm
  • Width dimension: 18.9 mm
  • Type of mounting: With H-rail
  • Max. number of modules: 10
Get a Quote

Current response time:

4 Minutes 9 Seconds
  • Description: Bus Module
  • Ambient temperature: -5 °C ... 50 °C
  • Dimensions W x L x H: 42.2 mm x 76.5 mm x 125.8 mm
  • Width dimension: 18.9 mm
  • Type of mounting: With H-rail
  • Max. number of modules: 10
  • Mounting position: Vertical - Horizontal
  • Note on ambient temperature: -5 - 60 °C for vertical installation
  • Storage temperature: -20 °C ... 70 °C
  • Relative air humidity: 95 % - Non-condensing
  • Degree of protection: IP20
  • Corrosion resistance class (CRC): 0 - No corrosion stress
  • Vibration resistance: Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6
  • Shock resistance: Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27
  • Protection against direct and indirect contact: PELV
  • LABS (PWIS) conformity: VDMA24364 zone III
  • CE marking (see declaration of conformity): As per EU EMC directive
  • Diagnostics via LED: Force mode - Network error - Network status, port 1 - Network status, port 2 - Power supply for electronics/sensors - Load power supply - System fault - Maintenance required
  • Diagnostics via bus: Wire break - Short circuit - PROFIsafe addresses different - Parameterization error - Upper limit value violated - Over temperature - Lower limit value not complied with - Undervoltage
  • Fieldbus interface, type: Ethernet
  • Fieldbus interface, protocol: PROFINET IRT - PROFINET RT
  • Fieldbus interface, function: Bus connection, incoming/forwarding
  • Fieldbus interface, connection type: 2x socket
  • Fieldbus interface, connection technology: RJ45
  • Fieldbus interface, connection pattern: 00995789
  • Fieldbus interface, number of poles/wires: 8
  • Fieldbus interface, galvanic isolation: Yes
  • Fieldbus interface, transmission rate: 100 Mbit/s
  • Max. address capacity inputs: 64 byte
  • Fieldbus interface, max. address volume for inputs: 64 byte
  • Information on inputs: 62 bytes with I/O diagnostic interface - 62 bytes with status bits - 64 bytes without diagnostics
  • 62 bytes with I/O diagnostic interface 62 bytes with status bits 64 bytes without diagnostics: 64 byte
  • Fieldbus interface, max. address volume for outputs: 64 byte
  • Note on outputs: 62 bytes with I/O diagnostic interface - 64 bytes with status bits - 64 bytes without diagnostics
  • System parameter: Diagnostic memory - Fail-safe response - Force mode - System start
  • Module parameters: Channel alarms for undervoltage - Analog module process value representation
  • Configuration support: GSDML file
  • Additional functions: LLDP - MRP - MRPD - PROFINET FSU - PROFINET I&MO..3, 1..3 retentive memory possible - PROFINET Shared device - S2 system redundancy - SNMP
  • Power supply, function: Electronics and sensors
  • Power supply, type of connection: Terminal strip
  • Power supply, note on connection type: > 4 A and UL 2x terminal strip for power supply
  • Power supply, connection technology: Spring-loaded terminal
  • Power supply, connection pattern: 00995847
  • Power supply, number of pins/wires: 4
  • Nominal operating voltage DC for electronics/sensors: 24 V
  • Permissible voltage fluctuations for electronics/sensors: ± 25 %
  • Power supply, conductor diameter: 0.2 mm² ... 1.5 mm²
  • Power supply, information on conductor diameter: 0.2 - 2.5 mm² for flexible conductors without cable end sleeves
  • Max. power supply: 8 A
  • Intrinsic current consumption at nominal operating voltage for electronics/sensors: Typically 75 mA
  • Power failure buffering: 20 ms
  • Reverse polarity protection: 24 V sensor supply against 0 V sensor supply
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on CPX-E-PN . Santa Clara Systems carries 9,904 items from Festo.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

  • 4080497

Common Typos

    Appended Numbers

    • CPX-E-PN-A
    • CPX-E-PN-B
    • CPX-E-PN-C
    • CPX-E-PN-D
    • CPX-E-PN-E
    • CPX-E-PN-F
    • CPX-E-PN-G
    • CPX-E-PN-H
    • CPX-E-PN-I
    • CPX-E-PN-J
    • CPX-E-PN-K
    • CPX-E-PN-L
    • CPX-E-PN-M
    • CPX-E-PN-N
    • CPX-E-PN-O
    • CPX-E-PN-P
    • CPX-E-PN-Q
    • CPX-E-PN-R
    • CPX-E-PN-S
    • CPX-E-PN-T
    • CPX-E-PN-U
    • CPX-E-PN-V
    • CPX-E-PN-W
    • CPX-E-PN-X
    • CPX-E-PN-Y
    • CPX-E-PN-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo