XCSPL753
Out of Stock
Product Summary:
- Product weight: 0.21 lb(US) (0.095 kg)
- Range of product: Preventa Safety detection
- IP degree of protection: IP67 conforming to IEC 60529
- Width: 1.18 in (30 mm)
- Height: 6.34 in (161 mm)
Let Us Find It
Current response time:
8 Minutes 3 Seconds
- Description: Safety Switch
- Product weight: 0.21 lb(US) (0.095 kg)
- Range of product: Preventa Safety detection
- IP degree of protection: IP67 conforming to IEC 60529
- Standards: EN/IEC 60204-1EN/IEC 60947-5-1EN 1088/ISO 14119EN/ISO 12100CSA C22.2 No 14EN/IEC 60947-5-4UL 508
- Width: 1.18 in (30 mm)
- Height: 6.34 in (161 mm)
- Depth: 1.18 in (30 mm)
- Protective treatment: THTC
- [Ui] rated insulation voltage: 300 V conforming to CSA C22.2 No 14500 V (degree of pollution: 3) conforming to EN/IEC 60947-1300 V conforming to UL 508
- [Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-5-1
- Mechanical durability: 1000000 cycles
- Vibration resistance: 50 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
- Shock resistance: 50 gn 11 ms conforming to IEC 60068-2-27
- Electrical connection: Terminal
- Material: Plastic
- Number of poles: 2
- Head type: Turret head rotary lever
- Enclosure material: Polyamide PA66 fibre glass impregnated
- Cable outer diameter: 0.28...0.39 in (7...10 mm)
- Product or component type: Guard switch
- Positive opening: With NC contact
- Product certifications: CSABGUL
- Component name: XCSPL
- Tripping angle: 5 °
- Ambient air temperature for operation: -13...158 °F (-25...70 °C)
- Minimum torque for tripping: 0.88 lbf.in (0.1 N.m)
- Ambient air temperature for storage: -40...158 °F (-40...70 °C)
- Insulation: Double insulated
- Positive opening minimum torque: 2.21 lbf.in (0.25 N.m)
- Type of operator: Straight lever
- Contact code designation: A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1Q300, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1
- Operator direction information: Centred
- [Ithe] conventional enclosed thermal current: 10:00 AM
- Electrical shock protection class: Class II conforming to EN/IEC 61140
- Contacts type and composition: 1 NC + 1 NC
- Contact operation: Slow-break
- Resistance across terminals: <= 30 mOhm conforming to EN/IEC 60947-5-4
- Clamping connection capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
- Short-circuit protection: 10 A cartridge fuse type gG (gl)
- Cable entry: 1 entry tapped 1/2" NPT
- Safety level: Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
- Safety reliability data: B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear)
- Lever material: Stainless steel
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XCSPL753 . Santa Clara Systems carries 10,643 items from Telemecanique.
- Safety Switch Xcspl - Straight Lever - Centred - 2nc -1/2"npt
Alternates
Common Typos
- XC5P1753
- XC5P17S3
- XC5PI753
- XC5PI7S3
- XC5PL753
- XC5PL7S3
- XCSP1753
- XCSP17S3
- XCSPI753
- XCSPI7S3
- XCSPL7S3
Appended Numbers
- XCSPL753-A
- XCSPL753-B
- XCSPL753-C
- XCSPL753-D
- XCSPL753-E
- XCSPL753-F
- XCSPL753-G
- XCSPL753-H
- XCSPL753-I
- XCSPL753-J
- XCSPL753-K
- XCSPL753-L
- XCSPL753-M
- XCSPL753-N
- XCSPL753-O
- XCSPL753-P
- XCSPL753-Q
- XCSPL753-R
- XCSPL753-S
- XCSPL753-T
- XCSPL753-U
- XCSPL753-V
- XCSPL753-W
- XCSPL753-X
- XCSPL753-Y
- XCSPL753-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier