LTMR27DFM
In stock and ready to ship
Product Summary:
- Product weight: 1.17 lb(US) (0.53 kg)
- IP degree of protection: IP20
- Standards: CSA C22.2 No 14IEC 60947-4-1EN 60947-4-1UL 508IACS E10
- Device short name: LTMR
- Width: 3.58 in (91 mm)
- Description: motor controller LTMR TeSys T - 100..240 V AC 27 A for DeviceNet
- Product weight: 1.17 lb(US) (0.53 kg)
- IP degree of protection: IP20
- Standards: CSA C22.2 No 14IEC 60947-4-1EN 60947-4-1UL 508IACS E10
- Device short name: LTMR
- Width: 3.58 in (91 mm)
- Height: 2.4 in (61 mm)
- Depth: 4.82 in (122.5 mm)
- Protective treatment: 12 x 24 hour cycles conforming to EN/IEC 60068-2-3048 h conforming to EN/IEC 60070-2-11TH conforming to EN/IEC 60068
- [Ui] rated insulation voltage: 690 V conforming to CSA C22.2 No 14690 V conforming to EN/IEC 60947-1690 V conforming to UL 508
- [Uimp] rated impulse withstand voltage: 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-16 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-10.8 kV communication circuit conforming to EN/IEC 60947-4-1
- Operating altitude: <= 6561.68 ft. (2000 m) without derating
- Tightening torque: 4.42...5.31 lbf.in (0.5...0.6 N.m), 0.12 in (3 mm) flat screwdriver control circuit
- Connections - terminals: Connector, 1 flexible cable with cable end 0...0 in² (0.25...2.5 mm²) /AWG 24...AWG 14 control circuitConnector, 1 flexible cable without cable end 0...0 in² (0.2...2.5 mm²) /AWG 24...AWG 14 control circuitConnector, 1 flexible cable without cable end 0...0 in² (0.25...2.5 mm²) /AWG 24...AWG 14 control circuitConnector, 1 solid cable without cable end 0...0 in² (0.2...2.5 mm²) /AWG 24...AWG 14 control circuitConnector, 2 flexible cable with cable end 0...0 in² (0.2...1 mm²) /AWG 24...AWG 14 control circuitConnector, 2 flexible cable without cable end 0...0 in² (0.2...1.5 mm²) /AWG 24...AWG 14 control circuitConnector, 2 flexible cable without cable end 0...0 in² (0.5...1.5 mm²) /AWG 24...AWG 14 control circuitConnector, 2 solid cable without cable end 0...0 in² (0.2...1 mm²) /AWG 24...AWG 14 control circuit
- Range: TeSys
- Operating rate: 1800 cyc/h
- Product name: TeSys T
- [Us] rated supply voltage: 100...240 V AC 50/60 Hz
- Overvoltage category: III
- Associated fuse rating: 0.5 A gG control circuit4 A gG output
- Protection type: Earth-leakage protectionOverload (long time)Phase unbalanceOverloadReverse polarity protectionPhase failurePower factor variationLocked rotorThermal protectionLoad fluctuationThermal overload protection
- Product certifications: LROS (Lloyds register of shipping)RINACCCEACDNVRMRoSULKERIC-TickABSCSANOMGLBVATEX
- Short-circuit withstand: 100 kA conforming to EN/IEC 60947-4-1
- Product or component type: Motor controller
- Fire resistance: 1202 °F (650 °C) conforming to EN/IEC 60695-2-121760 °F (960 °C) conforming to UL 94
- Device application: Equipment monitoring and control
- Ambient air temperature for operation: -4...140 °F (-20...60 °C)
- Measurement current: 1.35...27 A
- Network and machine diagnosis type: Starting current and timePhase fault and earth fault trip countersRemaining operating time before overload trippingEvent recordingFault recordingRunning hours counter/operating timeWaiting time after overload trippingTrip context informationMotor control command recordingTrip history information
- Ambient air temperature for storage: -40...176 °F (-40...80 °C)
- Logic input number: 6
- Current consumption: 8...62.8 mA
- Input current: 3.1 mA at 100 V7.5 mA at 240 V
- Mechanical robustness: shocks half sine wave acceleration (15 Gn for 11 ms) conforming to EN/IEC 60068-2-27? vibrations mounted on symmetrical rail (1 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6? vibrations plate mounted (4 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
- Supply voltage limits: 93.5...264 V AC
- Input/output type: Logic input : 0...40 V and <= 15 mA 25 ms (at state 0)Logic input : 79...264 V and >= 2 mA 25 ms (at state 1)
- Communication port protocol: DeviceNet
- Maximum operating frequency: 2 Hz
- Bus type: DeviceNet ISO 1198 interface, addressing 1...64, transmission rate 125...500 kbit/s, terminal block with 4 twisted shielded pairs cable
- Load current: 5 A at 250 V AC logic output5 A at 30 V DC logic output
- Permissible power: 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
- Contacts type and composition: 1 NO + 1 NC fault signal3 NO
- Metering type: Average current IavgImbalance currentEarth-fault currentPhase current I1, I2, I3 RMSTemperature
- Measurement accuracy: 3 % power factor (cos ? > 0.6)+/- 30 min/year internal clock0,02 temperature5...15 % earth fault current internal measurement (for current > 0.2 A)1 % current1 % voltage (100...830 V)5 % active and reactive power5 % earth fault current external measurement (< 5 % or 0.01 A)
- Connection pitch: 0.2 in (5.08 mm)
- Pollution degree: 3
- Electromagnetic compatibility: electrostatic discharge 3 (8 kV air, 6 kV contact), conforming to EN/IEC 61000-4-2? fast transients immunity test other circuits level 3 (2 kV), conforming to EN/IEC 61000-4-4? fast transients immunity test on supply and relay outputs level 4 (4 kV), conforming to EN/IEC 61000-4-4? conducted RF disturbances (10 V), conforming to EN/IEC 61000-4-6? surges serial mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5? surges common mode (2 kV) communication, conforming to EN/IEC 61000-4-5? surges common mode (2 kV) control circuit, conforming to EN/IEC 61000-4-5? radiated RF fields 3 (10 V/m), conforming to EN/IEC 61000-4-3? voltage dips and interruptions immunity test (70 %, 500 ms), conforming to EN/IEC 61000-4-11? surges serial mode (0.5 kV) temperature sensor, conforming to EN/IEC 61000-4-5? surges common mode (1 kV) temperature sensor, conforming to EN/IEC 61000-4-5? surges serial mode (2 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5? surges common mode (4 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5
- Web services: Web server
- Compatibility code: LTMR
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LTMR27DFM . Santa Clara Systems carries 10,643 items from Telemecanique.
- Motor Controller Ltmr Tesys T - 100..240 V Ac 27 A For Devicenet
Alternates
Common Typos
- 1TMR27DFM
- 1TMRZ7DFM
- ITMR27DFM
- ITMRZ7DFM
- LTMRZ7DFM
Appended Numbers
- LTMR27DFM-A
- LTMR27DFM-B
- LTMR27DFM-C
- LTMR27DFM-D
- LTMR27DFM-E
- LTMR27DFM-F
- LTMR27DFM-G
- LTMR27DFM-H
- LTMR27DFM-I
- LTMR27DFM-J
- LTMR27DFM-K
- LTMR27DFM-L
- LTMR27DFM-M
- LTMR27DFM-N
- LTMR27DFM-O
- LTMR27DFM-P
- LTMR27DFM-Q
- LTMR27DFM-R
- LTMR27DFM-S
- LTMR27DFM-T
- LTMR27DFM-U
- LTMR27DFM-V
- LTMR27DFM-W
- LTMR27DFM-X
- LTMR27DFM-Y
- LTMR27DFM-Z
Customers Are Also Buying
-
OY2P303A0135
Wenglor
-
872C-D10NP30-D4
Allen Bradley
-
800FP-LF6
Allen Bradley
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier