- Description: power base - TeSys U - 32 A - no connections control
- Product weight: 1.91 lb(US) (0.865 kg)
- IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1
- Standards: CSA C22.2 No 14 type E, EN 60947-6-2, IEC 60947-6-2, UL 508 type E with phase barrier
- Device short name: LUB
- Width: 1.77 in (45 mm)
- Height: 5.71 in (145 mm)
- Depth: 4.96 in (126 mm)
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1 3
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 15000000 cycles
- Tightening torque: Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) flat, Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) Philips no 1, Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) flat, Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) Philips No 2
- Connections - terminals: Power circuit: screw clamp terminals 2 cable 0...0.01 in (1.5...6 mm) - cable stiffness: flexible - without cable end, Power circuit: screw clamp terminals 1 cable 0...0.02 in (1...10 mm) - cable stiffness: rigid - without cable end, Power circuit: screw clamp terminals 1 cable 0...0.01 in (1...6 mm) - cable stiffness: flexible - with cable end, Power circuit: screw clamp terminals 1 cable 0...0.02 in (2.5...10 mm) - cable stiffness: flexible - without cable end, Power circuit: screw clamp terminals 2 cable 0...0.01 in (1...6 mm) - cable stiffness: flexible - with cable end, Power circuit: screw clamp terminals 2 cable 0...0.01 in (1...6 mm) - cable stiffness: rigid - without cable end, Control circuit: without connection
- Range: TeSys
- [Ith] conventional free air thermal current: 32 A
- System Voltage: 230 V, 440 V, 500 V, 690 V
- Operating rate: 60 cyc/mn
- Product name: TeSys U
- [Uc] control circuit voltage: 110...220 V DC, 110...240 V AC 50/60 Hz, 24 V AC 50/60 Hz, 24 V DC, 48 V AC 50/60 Hz, 48...72 V DC
- Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27
- Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-27, 4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
- [Ie] rated operational current: 21 A at 690 V, 23 A at 500 V, 32 A at <= 440 V
- Utilization category: AC-44, AC-41, AC-43
- Poles description: 3P
- Operating time: 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 65 ms closing with LUCM control circuit, 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit
- Auxiliary contact composition: 1 NO + 1 NC
- Heat dissipation: 3 W for control circuit with LUCA, LUCB, LUCC, LUCD, 1.8 W for control circuit with LUCM
- Auxiliary contacts type: Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1, Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
- Immunity to micro breaks: 3 ms
- Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
- Product or component type: Non reversing power base
- Network frequency: 40...60 Hz
- Product certifications: CSA, ATEX, LROS (Lloyds register of shipping), GL, UL, ASEFA, DNV, ABS, BV, GOST, CCC
- Device application: Motor
- [Ics] rated service breaking capacity: 10 kA 500 V, 4 kA 690 V, 50 kA 230 V, 50 kA 440 V
- Suitability for isolation: Yes
- Typical current consumption: 200 mA at 24 V DC I maximum while closing with LUCM, 220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 25 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 25 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 45 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 45 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 75 mA at 24 V DC I rms sealed with LUCM, 80 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 90 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
- Safety reliability level: B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Ambient air temperature for operation: -13...140 F (-25...60 C) with LUCM, -13...158 F (-25...70 C) with LUCA, LUCB, LUCC, LUCD
- Ambient air temperature for storage: -40...185 F (-40...85 C)
- Fire resistance: 1202 F (650 C) conforming to IEC 60695-2-12, 1760 F (960 C) parts supporting live components conforming to IEC 60695-2-12
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
- Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2
- Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
- Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
- Non-dissipating shock wave: 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2, 1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2, 2 kV common mode 24...240 V AC conforming to IEC 60947-6-2, 2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
- Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUB320 . Santa Clara Systems carries 10,300 items from Telemecanique.
- Power Base - Tesys U - 32 A - No Connections Control
Alternates
Common Typos
- 1U8320
- 1U832O
- 1U83Z0
- 1U83ZO
- 1UB320
- 1UB32O
- 1UB3Z0
- 1UB3ZO
- IU8320
- IU832O
- IU83Z0
- IU83ZO
- IUB320
- IUB32O
- IUB3Z0
- IUB3ZO
- LU8320
- LU832O
- LU83Z0
- LU83ZO
- LUB32O
- LUB3Z0
- LUB3ZO
Appended Numbers
- LUB320-A
- LUB320-B
- LUB320-C
- LUB320-D
- LUB320-E
- LUB320-F
- LUB320-G
- LUB320-H
- LUB320-I
- LUB320-J
- LUB320-K
- LUB320-L
- LUB320-M
- LUB320-N
- LUB320-O
- LUB320-P
- LUB320-Q
- LUB320-R
- LUB320-S
- LUB320-T
- LUB320-U
- LUB320-V
- LUB320-W
- LUB320-X
- LUB320-Y
- LUB320-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier