- Description: Pressure Sensor
- Weight: Approx. 74 g (with 2-m 6.6' cable)
- Footnotes: *1 The focus range applies while in focus mode only. *2 A response time of 100 or 500 ms applies if the AP-47 is used. *3 The maximum current is 20 mA if the AP-V42W (P) is installed as an expansion unit. *4 Only the AP-V41AW (P) (Master) and AP-C40W (P) apply.
- Output: PNP output
- Material: Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate
- Accessories: Power supply code (2-m 6.6' cable with connector), head connector, and unit seal
- Applicable sensor head: AP-41M, AP-41, AP-43, AP-44
- Display power: 3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") Display cycle: 10 times/s
- Set and display range: -15 to +110% of F.S. *1
- Operation indicator: Red LED x 2 (corresponding to control output 1 and 2)
- Resolution - Standard mode - AP-41M: 0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar
- Resolution - Standard mode - AP-41: 0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar
- Resolution - Standard mode - AP-43: 0.001 mPa, 0.01 kgf/cm2, 0.01 bar
- Resolution - Standard mode - AP-44: 0.1 kPa, 1 mmHg, 0.1 inchHg, 0.02 psi, 0.001 bar
- Resolution - Standard mode - AP-48: 0.1 kPa, 0.001 kgf/cm2, 0.02 psi, 0.001 bar
- Resolution - Focus mode - AP-41M: 0.01 kPa, 0.1 mmHg, 0.01 inchHg, 0.002 psi, 0.1 mbar
- Resolution - Focus mode - AP-41: 0.01 kPa, 0.1 mmHg, 0.01 inchHg, 0.002 psi, 0.1 mbar
- Resolution - Focus mode - AP-43: 0.1 kPa, 0.001 kgf/cm2, 0.02 psi, 0.001 bar
- Resolution - Focus mode - AP-44: 0.02 kPa, 0.2 mmHg, 0.01 inchHg, 0.004 psi, 0.2 mbar
- Resolution - Focus mode - AP-48: 0.02 kPa, 0.2 kgf/cm2, 0.004 psi, 0.2 mbar
- Hysteresis: Variable (Standard: 0.5% of FS; high-resolution/focus mode: 0.1% of F.S.)
- Response time (chattering prevention function): 1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) *2
- I/O - Control output: PNP open collector 100 mA max. (at 30 V or below) *3 with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)
- Temperature characteristic: ±1% of F.S. or less
- I/O - Analog output (selectable): 1 to 5 V with load impedance of 1 k? max. (or zero-shift input selectable)*4
- I/O - Zero-shift input (selectable): Input time: 2 ms or more (or analog output selectable)
- Rating - Power voltage: 12 to 24 VDC ±10% with ripple (p-p) of 10% max.
- Rating - Power consumption - At 12 V - Normal: 960 mW (80mA) or less
- Rating - Power consumption - At 12 V - Eco mode: 660 mW (55mA) or less
- Rating - Power consumption - At 24 V - Normal: 1440 mW (60mA) or less
- Rating - Power consumption - At 24 V - Eco mode: 1080 mW (45mA) or less
- Environmental resistance - Ambient temperature: 0 to 50°C 32 to 122°F, no freezing
- Environmental resistance - Ambient humidity: 35 to 85% RH (No condensation)
- Environmental resistance - Vibration resistance: 10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AP-C40WP . Santa Clara Systems carries 2,109 items from Keyence.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- AP-C4OWP
Appended Numbers
- AP-C40WP-A
- AP-C40WP-B
- AP-C40WP-C
- AP-C40WP-D
- AP-C40WP-E
- AP-C40WP-F
- AP-C40WP-G
- AP-C40WP-H
- AP-C40WP-I
- AP-C40WP-J
- AP-C40WP-K
- AP-C40WP-L
- AP-C40WP-M
- AP-C40WP-N
- AP-C40WP-O
- AP-C40WP-P
- AP-C40WP-Q
- AP-C40WP-R
- AP-C40WP-S
- AP-C40WP-T
- AP-C40WP-U
- AP-C40WP-V
- AP-C40WP-W
- AP-C40WP-X
- AP-C40WP-Y
- AP-C40WP-Z
More Products Like This
Customers Are Also Buying
-
855T-B24GL4
Allen Bradley
-
1756-TBE
Allen Bradley
-
855E-B10SA3
Allen Bradley
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier